With the release of our version 2012 software, ACD/MS Manager has been discontinued. The functionality of our mass spectrometry product line can now be found in ACD/MS Workbook Suite.
Existing software users, review our Release Version 2012 Information or contact ACD/Labs to discuss migration plans. This product was retired in November 2012; as per our End-of-Life Policy, technical support will be provided until November 2014.

ACD/MS Manager allows you to process all types of mass spectrometric data, including data from Thermo, AB SCIEX, Waters, Agilent, Bruker, Varian, Shimadzu, and other instruments. Unify data processing, build fully searchable databases of mass spectra, and simplify the sharing of information and report generation.
| Vendor | Data Format | Import | Export | Extension | Comments |
|---|---|---|---|---|---|
| ACD/Labs | ACD/Labs | ![]() |
![]() |
*.spectrus, *.esp | |
| Agilent Technologies | 1100 Series LC/MSD Quad and Ion Trap Systems | ![]() |
*.ms, *.yep | DAD data and single chromatogram curve are imported also. Splitter available | |
| ChemStation | ![]() |
*.ms | Splitter available | ||
| LC TOF | ![]() |
*.wiff | |||
| MassHunter (6000 series) | ![]() |
*.bin | Entire *.D folder structure should be used. Agilent component requires Microsoft .NET version 2. DAD can be imported (V12) and MS/MS split controlled in newer versions | ||
| AB SCIEX | Analyst | ![]() |
*.wiff | Single mass spectra, LC-MS and most LC-MSn imported. Splitter available. UV data not currently imported | |
![]() |
See above | LightSight—Spectra are 'pushed' via ACD/Labs (NetCDF) | |||
| Analyst QS | ![]() |
*.wiff | Single mass spectra, LC-MS and most LC-MSn imported. Splitter available | ||
| Analyst TF | ![]() |
*.wiff | |||
| Applied Biosystems | Mariner Data Explorer ASCII LC/MS | ![]() |
*.txt | LC-MS data only | |
| Bruker Daltonics and Agilent Technologies | Agilent or Bruker LC/MS Ion Trap | ![]() |
*.yep | LC-MS and DAD data | |
| Bruker | Compass (accurate mass data) | ![]() |
*.d | Entire *.D folder structure should be used. Bruker component requires Microsoft .NET version 3.5. Possible issue noted for MaXis Impact data. | |
| Hitachi | LIT-TOF | ![]() |
*.dat | Not supported in ACD/Spectrus products | |
| M-8000 and D-7000 | ![]() |
*.msd; *.dad | LC-MS and DAD data | ||
| JEOL (Japan) | JEOL-DX | ![]() |
*.jsp, *.jpf, *.jmc | Single mass spectra and chromatogram curves | |
| JEOL K9 | ![]() |
*.spe | LC(GC)-MS data | ||
| LECO Corporation | ChromaTOF-HRT™ for Citius™ (LC) and Pegasus® (GC) HRTs | ![]() |
*.smp | GC/MS or LC/MS data; LC/MS with in-source CID provides separate precursor and fragment ion (isCID) channels | |
| MasCom MASPEC II32 Data System | MASPEC | ![]() |
*.ms2 | Single mass spectra and LC(GC)-MS data | |
| Matlab/Eigenvector Research | DSO format | ![]() |
![]() |
*.mat | Single mass spectra and LC(GC)-MS data |
| National Institute of Standards and Technology | NIST MS Software | ![]() |
*.msp | Uses Lib2NIST to convert .msp to supported format (.hpj or .sdf) | |
| NIST SDF Library | ![]() |
*.sdf | Splitter available | ||
| Shimadzu Corporation | LCMS-IT-TOF | ![]() |
*.lcd | LC-MS and LC-MSn data only. Requires vendor software on same computer. | |
| GCMSsolution | ![]() |
*.qgd | GC-MS data (v11) | ||
| LCMSsolution | ![]() |
*.qld | DAD data and single chromatogram curve are also imported. May require vendor software on same computer | ||
| Thermo Scientific | Xcalibur | ![]() |
*.raw | Data splitting by Scan Filter parameters is available; format is supported only for Windows NT 4.0, Windows 2000, Windows XP, and Windows 7. Splitter available, to v2.2 | |
| Finnigan ICIS II | ![]() |
*.dat | Splitter available | ||
| Galactic | ![]() |
*.spc | Export is available for single MS only | ||
| Unidata | netCDF | ![]() |
*.cdf, *.nc | Splitter available | |
| Varian, Inc. | 1200 | ![]() |
*.dat | Splitter available | |
| XMS | ![]() |
*.xms, *.sms | Splitter available | ||
| Saturn 2000 | ![]() |
*.sms | Splitter available | ||
| Waters Corporation | MassLynx | ![]() |
*.raw | All files in the folder containing the _functns.inf file are necessary for data import. Splitter available | |
| Micromass OpenLynx | ![]() |
*.rpt | Splitter available | ||
| Millennium32 (2D and 3D PDA data) | ![]() |
"Connect to" ability available | |||
| Empower (2D and 3D PDA data) and Empower 2 (2D and 3D PDA data) | ![]() |
"Connect to" ability available | |||
| Empower (3D MS data) | ![]() |
LC-MS data only | |||
| Open Source | ASCII | ![]() |
![]() |
*.txt | Single MS only |
| JCAMP | ![]() |
![]() |
*.dx, *.jdx | Splitter available | |
| mzML | ![]() |
![]() |
|||
| netCDF | ![]() |
![]() |
*.cdf, *.nc | Single MS and LC(GC)-MS data |
Add additional capabilities to ACD/MS Manager:
ACD/IntelliTarget screens samples for the presence or absence of known compounds specified by formula or monoisotopic mass. In the process [M+H]+ or [M-H]-, adduct, multimer, and fragment ions are automatically assigned.
ACD/IntelliXtract extracts all components in a given dataset, assigns [M+H]+ or [M-H]-, adduct, multimer, and fragment ions, and can reconstruct a pure component spectrum for each.
ACD/MS Fragmenter provides a convenient way to review the fragmentation pathways and possible structure configurations for a particular fragment automatically assigned to a spectral peak by ACD/MS Manager. You can also easily create a report illustrating the possible fragmentation scheme(s).
Full List of Processing Features
Full List of Database Features
| Vendor | Data Format | Import | Export | Extension | Comments |
|---|---|---|---|---|---|
| ACD/Labs | ACD/Labs | ![]() |
![]() |
*.spectrus, *.esp | |
| Agilent Technologies | 1100 Series LC/MSD Quad and Ion Trap Systems | ![]() |
*.ms, *.yep | DAD data and single chromatogram curve are imported also. Splitter available | |
| ChemStation | ![]() |
*.ms | Splitter available | ||
| LC TOF | ![]() |
*.wiff | |||
| MassHunter (6000 series) | ![]() |
*.bin | Entire *.D folder structure should be used. Agilent component requires Microsoft .NET version 2. DAD can be imported (V12) and MS/MS split controlled in newer versions | ||
| AB SCIEX | Analyst | ![]() |
*.wiff | Single mass spectra, LC-MS and most LC-MSn imported. Splitter available. UV data not currently imported | |
![]() |
See above | LightSight—Spectra are 'pushed' via ACD/Labs (NetCDF) | |||
| Analyst QS | ![]() |
*.wiff | Single mass spectra, LC-MS and most LC-MSn imported. Splitter available | ||
| Analyst TF | ![]() |
*.wiff | |||
| Applied Biosystems | Mariner Data Explorer ASCII LC/MS | ![]() |
*.txt | LC-MS data only | |
| Bruker Daltonics and Agilent Technologies | Agilent or Bruker LC/MS Ion Trap | ![]() |
*.yep | LC-MS and DAD data | |
| Bruker | Compass (accurate mass data) | ![]() |
*.d | Entire *.D folder structure should be used. Bruker component requires Microsoft .NET version 3.5. Possible issue noted for MaXis Impact data. | |
| Hitachi | LIT-TOF | ![]() |
*.dat | Not supported in ACD/Spectrus products | |
| M-8000 and D-7000 | ![]() |
*.msd; *.dad | LC-MS and DAD data | ||
| JEOL (Japan) | JEOL-DX | ![]() |
*.jsp, *.jpf, *.jmc | Single mass spectra and chromatogram curves | |
| JEOL K9 | ![]() |
*.spe | LC(GC)-MS data | ||
| LECO Corporation | ChromaTOF-HRT™ for Citius™ (LC) and Pegasus® (GC) HRTs | ![]() |
*.smp | GC/MS or LC/MS data; LC/MS with in-source CID provides separate precursor and fragment ion (isCID) channels | |
| MasCom MASPEC II32 Data System | MASPEC | ![]() |
*.ms2 | Single mass spectra and LC(GC)-MS data | |
| Matlab/Eigenvector Research | DSO format | ![]() |
![]() |
*.mat | Single mass spectra and LC(GC)-MS data |
| National Institute of Standards and Technology | NIST MS Software | ![]() |
*.msp | Uses Lib2NIST to convert .msp to supported format (.hpj or .sdf) | |
| NIST SDF Library | ![]() |
*.sdf | Splitter available | ||
| Shimadzu Corporation | LCMS-IT-TOF | ![]() |
*.lcd | LC-MS and LC-MSn data only. Requires vendor software on same computer. | |
| GCMSsolution | ![]() |
*.qgd | GC-MS data (v11) | ||
| LCMSsolution | ![]() |
*.qld | DAD data and single chromatogram curve are also imported. May require vendor software on same computer | ||
| Thermo Scientific | Xcalibur | ![]() |
*.raw | Data splitting by Scan Filter parameters is available; format is supported only for Windows NT 4.0, Windows 2000, Windows XP, and Windows 7. Splitter available, to v2.2 | |
| Finnigan ICIS II | ![]() |
*.dat | Splitter available | ||
| Galactic | ![]() |
*.spc | Export is available for single MS only | ||
| Unidata | netCDF | ![]() |
*.cdf, *.nc | Splitter available | |
| Varian, Inc. | 1200 | ![]() |
*.dat | Splitter available | |
| XMS | ![]() |
*.xms, *.sms | Splitter available | ||
| Saturn 2000 | ![]() |
*.sms | Splitter available | ||
| Waters Corporation | MassLynx | ![]() |
*.raw | All files in the folder containing the _functns.inf file are necessary for data import. Splitter available | |
| Micromass OpenLynx | ![]() |
*.rpt | Splitter available | ||
| Millennium32 (2D and 3D PDA data) | ![]() |
"Connect to" ability available | |||
| Empower (2D and 3D PDA data) and Empower 2 (2D and 3D PDA data) | ![]() |
"Connect to" ability available | |||
| Empower (3D MS data) | ![]() |
LC-MS data only | |||
| Open Source | ASCII | ![]() |
![]() |
*.txt | Single MS only |
| JCAMP | ![]() |
![]() |
*.dx, *.jdx | Splitter available | |
| mzML | ![]() |
![]() |
|||
| netCDF | ![]() |
![]() |
*.cdf, *.nc | Single MS and LC(GC)-MS data |