ACD/Method Development Suite for LC/UV
What's New
Version 10.0 to 11.0
Improvements to Automated Peak Matching
- Overlay UV spectra for comparison of components across injections
- New option to assign newly extracted components as Rejected or Irrelevant
- UV-Mutual Automated Peak Matching enhancements
- Specify the minimum number of injections in which a component must be detected in order to be Relevant
- Ignore components that are not detected at all pH values
- Improved quality of LC/UV peak picking
Improvements to Component Reconciliation
- Control the accuracy of component reconciliation
Enhanced Strategy Creation
- Update the instrument configuration over the course of a project to expand the experimental design space
- Column screening strategy creation now considers the % minimum organic value
- Merge or split waves
Advancements to the Table of Components
- Switch between the Table of Components (all components for the project are listed) and a new Table of Peaks (only components detected in the current experiment)
- Transfer peak labels between detectors (e.g., LC/DAD and single-wavelength chromatogram) from the same injection
- New command to erase all unassigned peaks
- New command to clear all peak labels
Changes to the Experiments Subwindow
- Two new data columns—number of rejected peaks, and number of unnamed peaks added to Experiments table
- Error check process for file reimport
Improved Ease-of-Use
- Create retention models for method optimization within the AutoChrom Console Task window
- Execute default commands on double-click for most subwindows
Additional Features
- Create ACD/ChromGenius databases from Method Development Suite projects
Download a PDF copy of the expanded details on What's New with ACD/Method Development Suite for LC/UV, or contact your Account Manager or Distributor.
Version 9.0 to 10.0
ACD/Method Development Suite has been renamed ACD/Method Development Suite for LC/UV for version 10.0. You may also be interested in new ACD/Method Development Suite for LC/MS, which provides additional support for LC/MS data.
Automated Peak Matching between LC/UV Datasets
Project Management
- Manage and summarize all files associated with method development project:
- View a collapsible Table of Peaks which summarizes your injections
- Manage and summarize composite samples, and visualize composite chromatograms
- Store your experimental data and LC Simulator predictions in one place, to quickly understand the rationale behind your experiments
- View chromatograms and spectra alongside your peak tables
Method Development Assistant
- Guided method development
- Configure method development strategies
- Software suggests the next experiment based on ACD/LC Simulator optimization
New Processing Features
- Automatic attachment of chemical structures from an SDfile to labeled chromatographic peaks
- Automatic attachment of chemical structures to chromatograms by sample name
LC/UV Processing
- Peak picking for LC/UV (DAD, PDA) datafiles, not simply the Total Absorbance Chromatogram as in previous versions
- Retention time, peak height, and wavelength of the peak maximum in the UV-spectrum are added to the Table of Peaks
- UV-spectrum is retained
- Automatic baseline correction for LC/UV datafiles removes the spectrum of the solvent background
- Peak picking now available for Single UV-Trace(s0, not simply the Total Absorbance Chromatogram
- Transfer peak information from one LC/UV dataset to another with Manual Peak Matching tool
Enhancements to file import:
- Method parameters may now be imported directly from 32-bit Agilent ChemStation files.
- Import is now available for Waters Empower 2 files.
- Includes direct import of LC/UV (PDA) files.
- Direct import of HPLC parameters and gradient program(s) from Waters MassLynx LC/UV (PDA) files.
- Direct import of HPLC parameters and gradient program(s) from Agilent ChemStation LC/UV (DAD) files
ACD/Chromatography Applications Database increased in size, and now contains 7349 applications.
|