ACD/AutoChrom
Full List of Features
Method Selection & Optimization
- Search the built-in ACD/Chromatography Applications Database or a database of your own methods for a suitable starting point
- Predict retention times so that archived separations can be evaluated and modified before the first injection
- Optimize for pH based solely on analyte structure. Accurate structure-based pKa prediction algorithms are incorporated into ACD/LC Simulator.
- Design your method development strategy, and AutoChrom will automatically generate method sequences for:
- Agilent ChemStation
- Waters Empower 2 Software
- Specify success criteria for your method
- Create flexible method development strategies to optimize method development variables
- Update and refine strategies over the course of a project
- Design experimental waves to optimize method variables
- Select the best result of screening experiments:
- Column selection
- Mobile phase selection
- Buffer selection
- Optimize:
- Gradient
- Temperature
- Combined gradient and temperature
Data Interpretation
- Import LC/UV (PDA, DAD) records associated with chromatography data from most major instrument vendors.
- Process and collate many types of chromatographic data including:
- LC/MS
- LC/UV (PDA, DAD)
- Single UV-wavelength chromatograms
- Perform peak picking, smoothing, baseline correction, peak integration, and peak deconvolution on single chromatograms
- Import (export) structures from (to) an SDfile. The files can contain compound names and retention times.
- Manually assign chemical structures to peaks on your chromatogram via ACD/ChemSketch or from the table of peaks
- Automatically match peaks between injections, or between runs, based on spectral similarity for LC/UV and LC/MS datasets
- Peak labels and structures are copied from one data set to the next. If no peak labels exist, AutoChrom assigns a label to both datasets.
Project Management
- Manage your project using the dashboard overview
- Dig down into the original data when necessary to review or reprocess
- View a collapsible Table of Peaks which summarizes your injections
- Manage and summarize composite samples, and visualize composite chromatograms
- Store your experimental data and LC Simulator predictions in one place, to quickly understand the rationale behind your experiments
- View chromatograms and UV-spectra or mass spectra alongside your peak tables
- Reconcile peaks across detectors, or across samples
- Automatically update all related files with chemical structures
- Ignore irrelevant peaks without deleting the information from the dataset
Databasing
- Build a database of in-house methods, complete with method parameters, chromatograms, and chemical structures
- Share your databases within your organization to build a company-wide repository of chromatographic knowledge
- Retrieve previous separation methods from the ACD/Chromatography Applications Database or your own database of separations:
- Perform a simple structure, substructure, or structure similarity search of the database to retrieve methods for compounds similar to those in your sample
- Perform a Chromatographic Smart Search to not only retrieve separations of similar compounds, but also to estimate the retention times and evaluate the suitability of the found separations for your novel compounds
- Additionally, search the database(s) by method parameters, or other user data
Full List of Supported Hardware
Agilent & Waters Hardware
Agilent
| Pumps |
1100/1200 Quaternary Pump with Degasser |
G1354A (equivalent to G1311A+G1322A) |
| 1100/1200 Binary Pump (solvent selection option) |
G1312A (option #031) |
| 1200 Binary Pump SL (solvent selection option) |
G1312B (option #031) |
| 1290 Infinity Binary Pump |
G4220A, G4220B |
| 1290 Infinity Quaternary Pump |
G4204A |
| Column/Value Organization |
1100/1200 Column Thermostat (column selection option = 2pos/6port valve) |
G1316A (option #056) |
| 1200 Column Thermostat SL (column selection option = 2pos/6port valve) |
G1316B (option #056) |
| 1200 Column Thermostat SL+ (column selection
option = 2pos/6port or 8pos/9port or 6pos/14port
valve) |
G1316C (option #056/058/???) |
| Injection Systems |
1100/1200 Autosampler |
G1313A |
| 1100/1200 Thermostatted Autosampler |
G1329A* |
| 1100/1200 Well-plate Autosampler |
G1367A |
| 1200 High Performance Autosampler SL |
G1367C |
| 1200 Autosampler SL |
G1329B |
| 1200 High Performance Autosampler SL+ |
G1367D |
| Detectors |
1100/1200 Diode Array Detector |
G1315B |
| 1200 SL Diode Array Detector |
G1315C |
| 1200 Variable Wavelength Detector SL |
G1314B |
| 1290 Infinity Diode Array Detector |
G4212A, G4212B |
| MS Detectors |
Quadrupole LC/MS system |
G1946, G1956 |
| Quadrupole LC/MS system (fast scanning) |
G6140A |
| Agilent Single Quad Superior Line LC/MS |
G6130A |
| Valves |
1100/1200 6PS (Column Selection) Valve |
G1159A |
| 1100/1200 12PS/13PT (Solvent Selection) Valve |
G1160A |
| ChemStation Software |
Rev. B.02.01, B.03.01, B.04.01, B.04.02,
B.04.03 |
|
| Rev. C.01.04 |
|
* Partial support. Does not include temperature control.
Waters
| Alliance HPLC System |
Alliance chromatographic system (with Column Heater/Cooler) |
W2690/5 |
| Waters 3100 Mass Detector |
W3100 |
| Waters 2996 PDA Detector |
W2996 |
| Waters 996 PDA Detector |
996 PDA |
| Waters 2998 PDA Detector |
W2998 |
|
Rheodyne Solvent Selector connected to W2690/5 or W3100 |
|
| ACQUITY UPLC System |
Acquity UPLC Binary Solvent Manager |
ACQ-BSM |
| Acquity UPLC Column Manager |
ACQ-CM |
| Acquity UPLC Sample Manager |
ACQ-SM |
| Acquity UPLC PDA Detector/Extended Wavelength PDA Detector |
ACQ-PDA |
| Acquity UPLC SQ Detector |
ACQ-SQD |
| Acquity UPLC TQ Detector |
ACQ-TQD |
| ACQUITY UPLC H-Class System |
Acquity UPLC H-Class Sample manager (Flow
Through Needle) |
ACQ-FTN |
| Acquity UPLC H-Class Quaternary Solvent
Manager |
ACQ-QSM |
| Acquity UPLC Auxiliary Column Manager |
ACQ-CM-AUX |
|
Rheodyne Solvent Selector connected to ACQ-CM, ACQ-BSM, ACQ-SQD or ACQ-TQD |
|
|
Alternative detectors (not tested yet) |
Acquity 2996 PDA Detector |
ACQ-2996 |
| Acquity UPLC TUV
Detector |
ACQ-TUV |
| Acquity UPLC FLR Detector |
ACQ-FLR |
| Acquity UPLC ELS Detector |
ACQ-ELSD |
| Waters 2420 ELS Detector |
W2420 |
| Waters 2424 ELS Detector |
W2424 |
| Empower 2 Software |
Personal Installations: Feature Release 4 (PDA only) |
|
| Personal Installations: Feature Release 5 |
|
| Workgroup/Enterprise Installations |
|
| Empower
3 Software |
Personal/Workgroup/Enterprise Installations |
|