ACD/AutoChrom

Full List of Features

Method Selection & Optimization
  • Search the built-in ACD/Chromatography Applications Database or a database of your own methods for a suitable starting point
  • Predict retention times so that archived separations can be evaluated and modified before the first injection
  • Optimize for pH based solely on analyte structure. Accurate structure-based pKa prediction algorithms are incorporated into ACD/LC Simulator.
  • Design your method development strategy, and AutoChrom will automatically generate method sequences for:
    • Agilent ChemStation
    • Waters Empower 2 Software
  • Specify success criteria for your method
  • Create flexible method development strategies to optimize method development variables
  • Update and refine strategies over the course of a project
  • Design experimental waves to optimize method variables
  • Select the best result of screening experiments:
    • Column selection
    • Mobile phase selection
    • Buffer selection
  • Optimize:
    • Gradient
    • Temperature
    • Combined gradient and temperature
Data Interpretation
  • Import LC/UV (PDA, DAD) records associated with chromatography data from most major instrument vendors.
  • Process and collate many types of chromatographic data including:
    • LC/MS
    • LC/UV (PDA, DAD)
    • Single UV-wavelength chromatograms
  • Perform peak picking, smoothing, baseline correction, peak integration, and peak deconvolution on single chromatograms
  • Import (export) structures from (to) an SDfile. The files can contain compound names and retention times.
  • Manually assign chemical structures to peaks on your chromatogram via ACD/ChemSketch or from the table of peaks
  • Automatically match peaks between injections, or between runs, based on spectral similarity for LC/UV and LC/MS datasets
  • Peak labels and structures are copied from one data set to the next. If no peak labels exist, AutoChrom assigns a label to both datasets.
Project Management
  • Manage your project using the dashboard overview
  • Dig down into the original data when necessary to review or reprocess
  • View a collapsible Table of Peaks which summarizes your injections
  • Manage and summarize composite samples, and visualize composite chromatograms
  • Store your experimental data and LC Simulator predictions in one place, to quickly understand the rationale behind your experiments
  • View chromatograms and UV-spectra or mass spectra alongside your peak tables
  • Reconcile peaks across detectors, or across samples
  • Automatically update all related files with chemical structures
  • Ignore irrelevant peaks without deleting the information from the dataset
Databasing
  • Build a database of in-house methods, complete with method parameters, chromatograms, and chemical structures
  • Share your databases within your organization to build a company-wide repository of chromatographic knowledge
  • Retrieve previous separation methods from the ACD/Chromatography Applications Database or your own database of separations:
    • Perform a simple structure, substructure, or structure similarity search of the database to retrieve methods for compounds similar to those in your sample
    • Perform a Chromatographic Smart Search to not only retrieve separations of similar compounds, but also to estimate the retention times and evaluate the suitability of the found separations for your novel compounds
    • Additionally, search the database(s) by method parameters, or other user data
Full List of Supported Hardware

Agilent & Waters Hardware

Agilent

Pumps 1100/1200 Quaternary Pump with Degasser G1354A (equivalent to G1311A+G1322A)
1100/1200 Binary Pump (solvent selection option) G1312A (option #031)
1200 Binary Pump SL (solvent selection option) G1312B (option #031)
Column/value Organization 1100/1200 Column Thermostat (column selection option = 2pos/6port valve) G1316A (option #056)
1200 Column Thermostat SL (column selection option = 2pos/6port valve) G1316B (option #056)
Injection Systems 1100/1200 Autosampler G1313A
1100/1200 Thermostatted Autosampler G1329A*
1100/1200 Well-plate Autosampler G1367A
1200 High Performance Autosampler SL G1367C
1200 Autosampler SL G1329B
Detectors 1100/1200 Diode Array Detector G1315B
1200 SL Diode Array Detector G1315C
1200 Variable Wavelength Detector SL G1314B
MS Detectors Quadrupole LC/MS system G1946, G1956
Quadrupole LC/MS system (fast scanning) G6140A
Valves 1100/1200 6PS (Column Selection) Valve G1159A
1100/1200 12PS/13PT (Solvent Selection) Valve G1160A
ChemStation Software Version B.2.01  
Version B.3.01  

* Partial support. Does not include temperature control.

Waters

Alliance HPLC System Alliance chromatographic system (with Colum Heater/Cooler) W2695
Mass Detector W3100
2996/996 PDA Detector  
SQ Detector  
ACQUITY UPLC System Binary Solvent Manager  
Column Manager(this module is required for Acquity support)  
Sample Manager  
PDA Detector/Extended Wavelength PDA Detector  
SQ Detector  
TQ Detector  
Empower 2 Software Personal Installations: Feature Release 4 (PDA only)  
Personal Installations: Feature Release 5 (PDA and MS)  
Enterprise Installations (PDA only)  
Additional Components Rheodyne Solvent Selector (6, 10 positions)