ACD/ChromProcessor
Features
Processing
- Import chromatographic data from Waters Millennium32, Empower, and Empower 2; Dionex Chromeleon 6; PerkinElmer TotalChrom 6.1 and Turbochrom 4; Agilent ChemStation; NetCDF (AIA); and ASCII formats
- Import LC/UV (PDA, DAD) records associated with chromatography data from Agilent ChemStation, Waters MassLynx, Waters Empower, and Dionex Chromeleon 6
- Perform peak picking, smoothing, baseline correction, peak integration, and peak deconvolution on single chromatograms
- Perform peak picking and baseline correction for LC/UV datasets
- Import (export) structures from (to) an SDfile; the files can contain compound names and retention times
- Manually assign chemical structures to peaks on your chromatogram
- Automatically assign chemical structures from an SDfile to labeled chromatogram peaks
- Attach multiple structures to a co-eluting peak
- Automate standard processing steps with a macro program
- Record all processing actions into the Audit Trail; transfer the Audit Trail to create a macro program to apply to subsequent data sets
- Display a series of chromatograms on a single plot with structures, peak data, and annotations
- Export chromatographic data to ACD/Labs Spectrum, NetCDF, and ASCII formats
Reporting
- Produce professional reports with one chromatogram or a series, structure assignments, method parameters, peak tables, annotations, and more
- Add the table of structures containing chemical structures and peak data to your reports
- Create custom templates with your company logo for unified appearance of reports
- Create reports as Adobe PDF files
- Print reports according to the built-in or customized templates
- Transfer reports to other applications, such as Microsoft Word
Compatible Data Formats
| Vendor |
Data Format |
Import |
Export |
File Format |
| ACD/Labs |
Spectrus |
 |
 |
*.spectrus |
| ChromManager or Spectrus |
 |
 |
*.esp |
| Matrix |
 |
 |
*.txt |
| ASCII |
|
 |
 |
*.txt; *.prn; *.csv; *.asc |
| Agilent |
ChemStation1 |
 |
|
Entire *.D folder should be used*.ms, *.ch, *.uv1 |
| EZChrom4 |
 |
|
*.dat |
| Dionex® |
Chromeleon® 6 1,2 |
 |
|
|
| MATLAB® |
DSO 1 |
 |
 |
*.mat |
| PerkinElmer® |
TotalChrom™ 2 |
 |
|
*.raw, *.rst, *.sep, *.sum |
| Turbochrom™ 4 |
 |
|
*.rax |
| Shimadzu Corporation |
LabSolutions1,3 |
 |
|
*.lcd |
| Unidata |
netCDF |
 |
 |
*.cdf, *.nc |
| Waters® |
Millennium® 32 1 |
 |
|
|
| Empower™ Empower 2 and 3 1,2 |
 |
|
|
| MassLynx 1 |
 |
|
Entire *.raw folder should be used |
| Empower LCUV data 1 |
 |
|
*.arw |
| Thermo Fisher Scientific |
Generalized Analytical XML |
 |
 |
*.gaml |
1 Support for hyphenated data involving Diode Array Detector (DAD)
2 "Connect To"
3 For importing *.lcd files from the latest version 5.42SP2 we need in vendor's software, installed on the same computer
4 For importing *.dat files we need in vendor's software, installed on the same computer