Non-targeted Screening of MS Data with IntelliXtract

Quickly extract relevant components from LC/MS data.

ACD/MS Workbook Suite includes IntelliXtract, which extracts all chromatographic components in LC/MS datasets, and assigns [M+H]+ or [M-H]- for each component. Whether used to complement manual data examination, or for fully automated analysis, IntelliXtract can reduce interpretation time and confirm the presence of co-eluting or trace components which otherwise may have been overlooked. IntelliXtract will help analysts quickly understand their results, and extract the information of interest.

Features

  • Automatically assign [M+H]+ or [M-H]- for each component
  • Resolve overlapping peaks and identify co-eluting components
  • View reconstructed pure component spectra for each chromatographic component
  • Automatically analyze batches of samples

IntelliXtract uses a unique algorithm based on the CODA technology used by ACD/MS Workbook Suite. The process, called 'componentization' begins with peak extraction, followed by interpretation of the mass spectrum associated with each extracted component. This step considers the expected 12C/13C ratios, adducts, multimers, isotopes, neutral losses, and fragment ions, providing reliable spectrum interpretation and protonated or deprotonated molecule assignment.

Componentization ensures that all relevant components are detected, even when they exist only at trace concentrations, or co-elute with other components. The automation options and advanced filters reduce the interpretation time for increased efficiency.

Additional Resources

Full List of Features

General Features

  • Compatible with positive or negative ionization mode data
  • Compatible with different ionization modes (ESI, APCI, APPI, EI, CI, LC-FAB, etc.)
  • Work with mass accuracies from 0.00001 to 1 Da
  • Create a user-defined list of compound names and masses that may be present in the sample, and automatically add a label to the associated molecular ion peak
  • Label metabolite components based on the mass(es) of the parent drug(s), and a pre-defined list of phase I and phase II transformations (included with the software)
  • Label transformations from the parent compound(s) (e.g., neutral losses) with a user-defined table of modifications which may be saved and retrieved for different types of analyses
  • Annotate chromatogram peaks with the mass of the protonated or deprotonated molecule
  • Automatically attach chemical structures to components
  • Use macros to automatically process several data files with different parent compounds in batch mode

Chromatographic Processing Features

  • Accurately determine retention times of eluting compounds
  • Deconvolute overlapping components
  • Automatically calculate neutral losses for all components based on the difference between the (de)protonated molecule and possible fragment ions (PFI)
  • Apply flexible data pre-smoothing and baseline correction to single ion chromatograms
  • Extract high resolution mass chromatograms
  • Apply a mass defect filter
  • Apply an isotope pattern filter

Mass Spectral Processing Features

  • Automatically assign [M+H]+ or [M-H]-, adduct ions, multimers, neutral losses, and possible fragment ions for each component
  • Extract pure component spectra from overlapping components
  • Automatically classify the quality of the data for extracted components as Good, Poor, or Requires Manual Review
  • Calculate the average peak, peak top, and peak shoulder masses for the molecular ion and all other contributing ions within a component
  • Evaluate the peak quality of extracted single ion peaks based on peak height, area, symmetry, full width half maximum, S/N, 12C/13C, or a combination of parameters
  • Evaluate the spectrum quality. Apply pre-defined error limits for mass accuracy, 12C/13C, %M Ion, and isotope cluster analysis, or apply user-defined limits
  • Automatically assign common adduct ions (Na, K, NH3, and more)
    • Customize the list of possible adducts with a user-defined list
  • Selectively search for proton and adduct multimers
  • Automatically assign radical cations

Comparison Features

  • Identify similarities and differences between two or more datasets
    • Find unique peaks
    • Find differences between datasets based on user-defined differences in retention time or intensity
    • Find peaks common to the datasets
    • Apply Boolean comparison of peaks between datasets (present/not present)
    • Use isotope patterns to compare ion clusters between samples to confirm that similar components have similar spectral properties
  • Calculate the relative differences between different components based on the contributing ions
  • Compare components based on the contributing ion patterns using definable error tolerances

Supported File Formats

Vendor Data Format Import Export Extension Comments
ACD/Labs ACD/Labs checkmark checkmark *.spectrus, *.esp
Agilent Technologies 1100 Series LC/MSD Quad and Ion Trap Systems checkmark *.ms, *.yep DAD data and single chromatogram curve are imported also. Splitter available
ChemStation checkmark *.ms Splitter available
LC TOF checkmark *.wiff  
MassHunter (6000 series) checkmark *.bin Entire *.D folder structure should be used. Agilent component requires Microsoft .NET version 2. DAD can be imported (V12) and MS/MS split controlled in newer versions
AB SCIEX Analyst checkmark *.wiff Single mass spectra, LC-MS and most LC-MSn imported. Splitter available. UV data not currently imported
checkmark See above LightSight—Spectra are 'pushed' via ACD/Labs (NetCDF)
Analyst QS checkmark *.wiff Single mass spectra, LC-MS and most LC-MSn imported. Splitter available
Analyst TF checkmark *.wiff
Applied Biosystems Mariner Data Explorer ASCII LC/MS checkmark *.txt LC-MS data only
Bruker Daltonics and Agilent Technologies Agilent or Bruker LC/MS Ion Trap checkmark *.yep LC-MS and DAD data
Bruker Compass (accurate mass data) checkmark *.d Entire *.D folder structure should be used. Bruker component requires Microsoft .NET version 3.5. Possible issue noted for MaXis Impact data.
Hitachi LIT-TOF checkmark *.dat Not supported in ACD/Spectrus products
M-8000 and D-7000 checkmark *.msd; *.dad LC-MS and DAD data
JEOL (Japan) JEOL-DX checkmark *.jsp, *.jpf, *.jmc Single mass spectra and chromatogram curves
JEOL K9 checkmark *.spe LC(GC)-MS data
LECO Corporation ChromaTOF-HRT™ for Citius™ (LC) and Pegasus® (GC) HRTs checkmark *.smp GC/MS or LC/MS data; LC/MS with in-source CID provides separate precursor and fragment ion (isCID) channels
MasCom MASPEC II32 Data System MASPEC checkmark *.ms2 Single mass spectra and LC(GC)-MS data
Matlab/Eigenvector Research DSO format checkmark checkmark *.mat Single mass spectra and LC(GC)-MS data
National Institute of Standards and Technology NIST MS Software checkmark *.msp Uses Lib2NIST to convert .msp to supported format (.hpj or .sdf)
NIST SDF Library checkmark *.sdf Splitter available
Shimadzu Corporation LCMS-IT-TOF checkmark *.lcd LC-MS and LC-MSn data only. Requires vendor software on same computer.
GCMSsolution checkmark *.qgd GC-MS data (v11)
LCMSsolution checkmark *.qld DAD data and single chromatogram curve are also imported. May require vendor software on same computer
Thermo Scientific Xcalibur checkmark *.raw Data splitting by Scan Filter parameters is available; format is supported only for Windows NT 4.0, Windows 2000, Windows XP, and Windows 7. Splitter available, to v2.2
Finnigan ICIS II checkmark *.dat Splitter available
Galactic checkmark *.spc Export is available for single MS only
Unidata netCDF checkmark *.cdf, *.nc Splitter available
Varian, Inc. 1200 checkmark *.dat Splitter available
XMS checkmark *.xms, *.sms Splitter available
Saturn 2000 checkmark *.sms Splitter available
Waters Corporation MassLynx checkmark *.raw All files in the folder containing the _functns.inf file are necessary for data import. Splitter available
Micromass OpenLynx checkmark *.rpt Splitter available
Millennium32 (2D and 3D PDA data) checkmark "Connect to" ability available
Empower (2D and 3D PDA data) and Empower 2 (2D and 3D PDA data) checkmark "Connect to" ability available
Empower (3D MS data) checkmark LC-MS data only
Open Source ASCII checkmark checkmark *.txt Single MS only
JCAMP checkmark checkmark *.dx, *.jdx Splitter available
mzML checkmark checkmark
netCDF checkmark checkmark *.cdf, *.nc Single MS and LC(GC)-MS data