ACD/1D NMR Manager
What's New
NOTE: Please refer to What's New in ACD/1D NMR Processor as this product is included when purchasing ACD/1D NMR Manager.
Version 10.0 to 11.0
Processing, Analysis, and Interpretation (features also available in ACD/1D NMR Processor)
- Improved automated multiplet analysis
- The algorithm used to automatically characterize coupling patterns and determine coupling constants has been improved
- Better first-order multiplet recognition when significant roofing effects are observed
- Assignment quality preview (requires ACD/HNMR Predictor)
- Uses NMR prediction to provide users with a real-time evaluation of assignment suitability
- Individual atoms are colored green, yellow, or red when a user hovers over a multiplet
- Green suggests a suitable match
- Yellow suggests a potential match
- Red suggests a poor match
- Shows all possible atom assignments for any multiplet in the spectrum
- New verification diagnostics (requires ACD/HNMR Predictor)
- Inconsistencies are now provided by the software when a structure verification does not pass:
- Major inconsistencies occur when the software is unable to assign an atom to a multiplet during the verification routine
- Minor inconsistencies occur when the software is not fully satisfied with an assignment and requires manual approval
- These diagnostic messages provide the user with descriptive detail on why the verification was not successful
- View the Calculation Protocol (requires ACD/HNMR and/or CNMR Predictor)
- Users can now view the NMR calculation protocol when a prediction or verification is run in the processing interface
- This is a nice consulting tool that allows the users to evaluate how many (and what types) of chemical structures were used to generate the predicted chemical shift
- Solvent-specific structure verification (requires ACD/HNMR and/or CNMR Predictor)
- Users can now choose from a list of solvents to perform structure verification
- When a solvent is selected, all database records that are not in the selected solvent will be omitted from consideration
- New formatting options for multiplet reports
- Users can now automatically format their multiplet reports in several different journal formats
- Users can also create their own customized journal formats for publications not currently supported
- Improved integral labels
- A new integral labeling layout has been adopted to avoid overlapping integral labels on a spectrum
- New manual offset procedure for spectra in a series
- When spectra are collected in a series, users can now change the visible locations of each spectrum with a simple click-and-drag
- Automatic detection for some solvents
- When entering peak picking or shortcut mode, the software will identify signals for TMS, DMSO, Water in DMSO, and Methanol and automatically create dark regions
- Lock integrals for multiplets
- Users now have the option to lock the integrals after they create a multiplet, so new multiplets that are created will not change the integration of the spectrum
- Assignment of diastereotopic protons
- When assigning multiplets to methylene protons, users will now have the option to assign protons separately or together, with the prime and double prime markers (', ")
- Label atoms in a chemical structure with assigned chemical shift values
- Users can now choose to view the chemical shifts of assigned atoms on the chemical structure
- Structure menu was added to the main menu bar
- To make it easier to find structure commands and functionality, a dedicated Structure menu was added on the menu bar
- Improved coloration options for spectra in a series
- Three color schemas can now be applied to a spectral series
- Selectively show/hide spectra in a series
- It is now possible to hide/show spectra from a series that are not immediately important through a check box
- Apply a macro equally across all selected files in the processor
- Instead of a macro being applied to the active file only, you are now given a choice to apply a macro to all currently selected files in the processor window
- Easy access to recently viewed files
- Displays a list of previously opened files
- Improved navigation
- Where possible, dialog boxes were replaced to provide direct navigation and reduce the number of clicks required for a specific task
- Processor windows can now be re-ordered in full screen mode
- Previously, multiplet windows could only be re-ordered in tile mode. Now, you can also change the ordering in full screen mode by dragging the tab of the appropriate window to its new position
Databasing
- View database search results in the Processor window
- Reference spectrum is automatically shown and synchronized with respect to hit results for improved visual comparisons
- Synchronized zooming functions
- Spectral subtraction in the case of multi-component mixtures
- Easily export search results to an Excel spreadsheet
- A "Push Data to Excel" command has been added that opens Microsoft Excel and pastes the data tables in a spreadsheet
- Color highlight search matches in database
- Search terms within the database are highlighted in the search results for easy identification
- Easily remove specific analytical data types from the entire database
- A "DeleteDocumentFromCurrentDB" macro command allows you to delete documents of a specified data type from the SpecDB record
Download a PDF copy of the expanded details on What's New with ACD/1D NMR Manager, or contact your Account Manager or Distributor.
- Shortcut Mode
- New workflow that allows you to manually prepare an NMR spectrum as quickly as possible.
- New and Improved J-Coupler Interface
- Easily delete a defined multiplet from within the J-Coupler dialog box
- Multiplet is automatically reanalyzed each time a peak is created or deleted
- Multiplet type is updated if you manually update a J-value
- Integration and peak peaking will be automatically performed (if necessary) if you define a multiplet range during manual multiplet definition
- Changes to multiplets are saved automatically
- New coupling patterns have been added (quintet, sextet, septet)
- Structure Exchange Tool
- Modify attached chemical structures without losing existing assignments.
- Intelligent Bucketing
- Analyze thousands of 1D NMR spectra at once.
Databasing
- Store and display images (BMP, JPEG, GIF, PNG, etc.) directly in the database screen form.
- Update user data across multiple database records in batch mode.
- Derive calculated values according to custom data scripting.
- Link related techniques in a clear hierarchical system.
Processing (Features also available in ACD/1D NMR Processor)
- Extract any user data fields when importing raw data.
- Perform automatic phasing using only the zeroeth order parameter.
- Manually phase spectra with vertical or horizontal mouse movements.
- Copy and paste signal-to-noise values.
Analysis (Features also available in ACD/1D NMR Processor)
- Improved multiplet analysis and assignment:
- Resolve overlapping multiplets during J-Coupler analysis.
- Automatically or manually connect multiplets with the same coupling constants.
- Create color-coded 2J, 3J, and long range correlation arrows on attached chemical structures.
- Coupling guided manual assignments: the software guides manual assignment by comparing the J values for the chemical structure to the multiplet J values.
- Improved verification:
- Verification reliability has been added to the verification results to account for peak overlap and hard to establish coupling patterns.
- Highlight verification results for each atom on the attached structure. The quality of the match is represented in the familiar green, yellow, and red verification results.
- Automatically compare manual assignments to automatic assignments in a side-by-side window.
Visualization
- Label spectra with color-coded multilayer annotations that can individually be toggled on and off.
- Display select information directly in the spectrum windowpane.
Databasing
- Apply the improved Forms Manager to the database
- Automatically use a specified input form when updating a given database
- Set different forms to be used for different types of spectra stored
- Use the improved Screen Forms Manager which stores a chosen screen layout in the database
- Highlight important fields in on screen or database forms by changing the font style
- Apply bold, italic, underline, or strikeout formatting and change the font size and color
- Enjoy enhanced display options and management for plate windows
- Support high throughput data with 384-well plates
- Manage and index plates with more ease with an improved set of dialog boxes
- Show plate name, dimension, coloration scheme name, axes, gridlines, and hints in the plate window
- Manipulate selected entries in a plate through a new set of commands
- Specify font and font style of your choice in the user notes
- Define font style in bold, italic, small caps, super and subscript, and change the font size and color
- Select alignment; left, right, and centered
- Copy and paste formatted text from and to the user notes
- Undo and redo formatting changes
Analysis
- Transfer of assignment between two 1D spectra
- Transfer the assignment of a 1D spectrum to a 2D experiment and vice versa
- Ignore dark regions during peak normalization
- Ignore the influence of extraneous peaks (i.e., solvent peaks) when scaling the spectrum
- Adjust the threshold using the mouse-wheel for vertical scaling of a spectrum
- Set a user-defined threshold or impurity detection in automatic multiplet analysis
- Linked cursors for synchronized 1D and 2D spectra.
- Negative line broadening and large positive values
- Enter both positive and negative values for Lorentzian-Gaussian function and negative values for line broadening
- Keep manual assignments when using the autoassignment procedure
- Use the same calculation method as used in the NMR predictors (1H, 13C)
- Supports solvent synonyms
- Enter as many solvent synonyms as desired and set one as the default to be used automatically in spectrum parameters, multiplet reports, etc.
- Use user-defined solvents when auto-referencing a spectrum
- Intelligent Bucketing (Metabonomics)
- Eliminate ambiguous results which occur when a metabolite signal "wanders" from one bucket to another between spectra
- Export integrals from multiple spectra to a common file
- Zero all negative integrals automatically before statistical analysis (PCA and PLS)
- Export integrals in standard JCAMP format
Processing
- Display vendor-specific directory structure
- Preview spectrum before opening a file
Visualization
- Customize color highlighting of experimental vs. predicted values
- Add a plot legend to the 1D NMR quantitation graphs
- Apply autocoloring to series of spectra
Advanced Tools
- Measure concentration changes with the Quantitation Tool, (Quanalyst)
- Monitor a degrading sample over time
- Compare quantitation between samples on a combinatorial plate
- Quantify ratios of components
- Check isomer ratios in a mixture
- Confirm the relative abundances within a copolymer
- Quantity handling
- Produce a macro to use on a batch of spectra
- Graph results and pass to ACD/Curve Manager for regression analysis
- Obtain the correlation between almost ANY spectral properties
Visualization
- Plot spectra in Absolute Intensity Mode
- Compare spectra by plotting on the same vertical scale
- Plot spectra in Normalized Mode
- Display according to the highest peak in the spectrum
- Modify the Toolbar content options
- Hide the uncommonly used buttons on the toolbar
Processing
- Open and manipulate arrayed experimental data
- Process, analyze, and report all spectra in an array simultaneously
- Treat as a group or manipulate individually
- Show selected spectral properties in the Table of Spectra
- Associate spectra into a series
- Treat individual spectra as an array by associating them
Databasing
- Use several databases simultaneously for a spectral prediction
- Internal and/or user databases
- Customize the viewing options for spectra in the database
- Choose view options such as vertical and horizontal zoom, peak labels, etc.
- Ignore the dark regions when searching a database
- Search a database by zoom region
- Search for a spectrum by similarity
- Use Absolute Difference or Euclidean Distance
- Sort the results by Hit Quality Index (HQI %)
- Search the database for a peak
- Search using labeled peaks only
- Use a looseness factor on peak shifts
- Search the database for a multiplet
- Use coupling patterns
- Use any range of J-coupling values
- Search the database using a mixture
- Search by peak(s) in one or more selected regions when a mixture is suspected
- Advanced searching
- Use the macro searching to find a solvent multiplet and annotate it automatically
- A useful tool for overlapping multiplets or peaks
Additional Capabilities
- Improved accuracy of integration
- Includes linear interpolation when integrating for accurate bucketing
- Correct the baseline on a selected region only
- Variable bucket sizes across a spectrum
- Change the orientation of the integral labels to vertical for easier viewing
- Calculate the Signal-to-Noise ratio (S/N) using the ASTM method
- Use any peak in the spectrum to calculate the S/N
- Use the minimum S/N as a threshold for peak-picking
- Automatically or manually select the noise region
Input/Output
- Create a multiplet report
- Customize the reporting format for different Journals
- Import the receiver gain parameter from an NMR data file
|